SLM-5650B Satellite Modem
Revision 2
Appendix C C–38 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
RTC Date DAY= 6 bytes Command or Query.
A date in the form ddmmyy, where:
dd = day of the month (01 to 31),
mm = month (01 to 12)
yy = year (00 to 99)
Example: DAY = 240457 (April 24, 2057)
DAY=
DAY?
DAY*
DAY#
DAY? DAY=ddmmyy
(see Description
of Arguments)
Eb/No Alarm
Point
EBA= 4 bytes Command or Query.
Eb/No alarm point in dB, with a range between 0.1 and 20 dB.
Resolution = 0.1 dB.
Example: EBA = 12.3
EBA=
EBA?
EBA*
EBA#
EBA? EBA=xx.x
(see Description
of Arguments)
Equipment ID
N/A 17 bytes Query only.
Unit returns information concerning the equipment identification,
and the option field, in the form aaaabcdefghijklmx where:
aaaa = defines the modem model number (565B = SLM-
5650B)
b = Advanced FEC:
1 = TPC
2 = TPC + LDPC
c = Reserved
d = Option Card:
0 = None
1 = G.703
2 = GigaBit Ethernet
3 = Reserved
4 = Network Processor
5 = LVDS
N/A EID?
EID=aaaabcdef
ghijklmx
(see Description
of Arguments)