SLM-5650B Satellite Modem
Revision 2
Appendix C C–53 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Power Level
AMX= 5 bytes Command or Query.
Maximum Tx Output power level, where:
s = sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm
Example: AMX = -13.4
AMX=
AMX?
AMX*
AMX#
AMX? AMX=sxx.x
(see Description of
Arguments)
Power Level
Nominal Tx Output power level, where:
s = sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm
Example: ANP = -13.4
ANP?
ANP*
ANP#
(see Description of
Arguments)
Baud Rate
Baud Rate, where:
0 = 110
1 = 150
2 = 300
3 = 600
4 = 1200
5 = 2400
6 = 4800
7 = 9600
8 = 19200
9 = 38400
Example: ARB = 0 (sets the ASYNC ESC Rx Baud Rate to 110
Baud)
ARB?
ARB*
ARB#
(see Description of
Arguments)