SLM-5650B Satellite Modem
Revision 2
Appendix C C–54 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Format
ARF= 2 bytes Command or Query.
Async Format, where:
00 = 7 Bits, No Parity, 1 Stop Bit
01 = 7 Bits, Even Parity, 1 Stop Bit
02 = 7 Bits, Odd Parity, 1 Stop Bit
03 = 7 Bits, No Parity, 2 Stop Bits
04 = 7 Bits, Even Parity, 2 Stop Bits
05 = 7 Bits, Odd Parity, 2 Stop Bits
06 = 8 Bits, No Parity, 1 Stop Bit
07 = 8 Bits, Even Parity, 1 Stop Bit
08 = 8 Bits, Odd Parity, 1 Stop Bit
09 = 8 Bits, No Parity, 2 Stop Bits
10 = 8 Bits, Even Parity, 2 Stop Bits
11 = 8 Bits, Odd Parity, 2 Stop Bits
Example: ARF = 0 (sets the ASYNC ESC Rx Format to 7N1)
ARF=
ARF?
ARF*
ARF#
ARF? ARF=xx
(see Description of
Arguments)
Sample Interval
Used to set the sample interval for the AUPC Logging Function in
the form x, where:
x = 0 to 9 in 10 minute steps.
Note: Setting this parameter to 0 disables the logging function.
Example: ASI = 3 (sets the logging inverval to 30 minutes)
ASI?
ASI*
ASI#
(see Description of
Arguments)