SLM-5650B Satellite Modem
Revision 2
Appendix C C–56 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
Log Entries
CAA= None Command only.
Forces the software to clear the software AUPC log.
Note: This command takes no arguments.
Example: AAS=
CAA=
CAA?
CAA*
CAA#
N/A N/A
Initialize AUPC
Log Pointer
IAP= None Command only.
Resets internal pointer to allow RNA? queries to start at the
beginning of the stored statistics log.
IAP=
IAP#
N/A N/A
AUPC Local
Carrier Loss
Action
LCL= 1 byte Command or Query.
Tx Output Power level setting when local carrier is lost, where:
0 = Hold current output power level
1 = Goto Nominal output power level
2 = Goto Maximum output power level
Example: LCL = 0
LCL=
LCL?
LCL*
LCL#
LCL? LCL=x
(see Description of
Arguments)
AUPC Local
Enable
LPC= 1 byte Command or Query.
Local AUPC Control, where:
0 = Off
1 = On
Note: When Local AUPC Control is enabled, modulator output
power is automatically controlled by the modem. Power output
commands via TPL are not allowed during this mode; although,
queries will function as normal.
Example: LPC = 1 (Turn on Local AUPC Control)
LPC=
LPC?
LPC*
LPC#
LPC? LPC=x
(see Description of
Arguments)
Number of
Unread AUPC
Log Entries
N/A 3 bytes Query only.
Unit returns the Number of AUPC Log Entries, which remain
Unread, in the form xxx.
Note: This means unread over the remote control.
Example: NUS = 126
N/A NUA? NUA=xxx
(see Description of
Arguments)