SLM-5650B Satellite Modem
Revision 2
Appendix C C–57 MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
unread AUPC
Log Entries
N/A 155 bytes Query only.
Unit returns the oldest 5 AUPC Log Entries which have not yet
been read over the remote control.
Reply format: {CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}
Sub-body{CR}Sub-body, where Sub-body=
AA.ABB.BCCC.CEEE.Eddmmyyhhmmss:
AA.A = Minimum Eb/No during sample period.
BB.B = Average Eb/No during sample period.
CCC.C = Max Output Power during sample period.
EEE.E = Average Output Power during sample period.
If there are less than 5 events to be retrieved, the remaining
positions are padded with zeros. If there are no new events, the
response is RNA*.
N/A RNA? RNA=
{CR}AA.ABB.BCCC
.CEEE.Eddmmyyhh
mmss{CR}
AA.ABB.BCCC.CE
EE.Eddmmyyhhmm
ss{CR}AA.ABB.BC
CC
.CEEE.Eddmmyyhh
mmss{CR}AA.ABB.
BCCC.CEEE.Eddm
myyh
hmmss{CR}AA.ABB
.BCCC.CEEE.Eddm
myyhhmmss
(see Description of
Arguments)
AUPC Remote
Carrier Loss
Action
RCL= 1 byte Command or Query.
Tx Output Power level setting when remote carrier is lost, where:
0 = Hold current output power level
1 = Goto Nominal output power level
2 = Goto Maximum output power level
Example: RCL = 0
RCL=
RCL?
RCL*
RCL#
RCL? RCL=x
(see Description of
Arguments)
Pattern
Substitution
Remote Modem Tx Pattern Substitution, where:
0 = Off
1 = On
Note: For compatibility reasons, only the 2047 Tx pattern can be
turned On or Off at the remote modem.
Example: RPB = 1 (Turn on remote modem AUPC Control)
RPB?
RPB*
RPB#
(see Description of
Arguments)