Unidrive SP Advanced User Guide 313
Issue Number: 7 www.controltechniques.com
The error status is provided so that only one Solutions Module error trip is required for each Solutions Module slot. If an error occurs the reason for
the error is written to this parameter and the drive may produce a SLX.Er trip, where X is the slot number. A value of zero indicates that the Solutions
Module has not detected an error, a non-zero value indicates that an error has been detected. (See section Solutions Module error status values on
page 301 for the meaning of the values in this parameter.) When the drive is reset this parameter is cleared for all Solutions Modules.
This Solutions Module includes a temperature monitoring circuit. If the PCB temperature exceeds 94°C, the drive fan is forced to operate at full speed
(for a minimum of 10s). If the temperature falls below 94°C, the fan can operate normally again. If the PCB temperature exceeds 100°C, the drive will
trip and the error status is set to 74.
Most Solutions Modules include a processor with software. The software version is displayed in these parameters in the form Pr x.02 = xx.yy and Pr
x.50 = zz. Where xx specifies a change that affects hardware compatibility, yy specifies a change that affects product documentation, and zz specifies
a change that does not affect the product documentation. When a module is fitted that does not contain software both these parameters appear as
zero.
x.50 Solutions Module error status
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111 1
Range Open-loop, Closed-loop, Servo, Regen 0 to 255
Update rate Background write
x.51 Option software sub-version
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
111 1
Range Open-loop, Closed-loop, Servo, Regen 0 to 99
Update rate Write on power-up
http://nicontrols.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques unidrive sp and is the answer not in the manual?

Control Techniques unidrive sp Specifications

General IconGeneral
BrandControl Techniques
Modelunidrive sp
CategoryController
LanguageEnglish

Related product manuals