5.19 Menu 20: Application menu 3
Menu 20 contains parameters that do not affect the operation of the drive. These general purpose parameters are intended for use with fieldbus and
application Solutions Modules. The read write parameters in this menu cannot be saved in the drive.
20.01 to 20.20 Application menu 3 read-write integer
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
11
Range
Open-loop, Closed-loop vector, Servo,
Regen
-32,768 to 32,767
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate N/A
20.21 to 20.40 Application menu 3 read-write long integer
Drive modes Open-loop, Closed-loop vector, Servo, Regen
Coding
Bit SP FI DE Txt VM DP ND RA NC NV PT US RW BU PS
11
Range
Open-loop, Closed-loop vector, Servo,
Regen
-2
31
to 2
31
-1
Default
Open-loop, Closed-loop vector, Servo,
Regen
0
Update rate N/A