CONFIGURATION mode
delay-restore delay-restore-time
The range is from 1 to 1200.
The default is 90 seconds.
Reconfiguring the Default VLT Settings (Optional)
To reconfigure the default VLT settings, use the following commands.
1 Enter VLT-domain configuration mode for a specified VLT domain.
CONFIGURATION mode
vlt domain domain-id
The range of domain IDs is from 1 to 1000.
2 After you configure a VLT domain on each peer switch and connect (cable) the two VLT peers on each
side of the VLT interconnect, the system elects a primary and secondary VLT peer device. To configure
the primary and secondary roles before the election process, use the primary-priority command. Enter a
lower value on the primary peer and a higher value on the secondary peer.
If the primary peer fails, the secondary peer (with the higher priority) takes the primary role. If the
primary peer (with the lower priority) later comes back online, it is assigned the secondary role (there is
no preemption).
3 (Optional) When you create a VLT domain on a switch, Dell Networking OS automatically creates a VLT-
system MAC address used for internal system operations.
VLT DOMAIN CONFIGURATION mode
system-mac mac-address mac-address
To explicitly configure the default MAC address for the domain by entering a new MAC address, use the
system-mac command. The format is aaaa.bbbb.cccc.
Also, reconfigure the same MAC address on the VLT peer switch.
Use this command to minimize the time required for the VLT system to synchronize the default MAC
address of the VLT domain on both peer switches when one peer switch reboots.
4 (Optional) When you create a VLT domain on a switch, Dell Networking OS automatically assigns a
unique unit ID (0 or 1) to each peer switch.
VLT DOMAIN CONFIGURATION mode
unit-id {0 | 1}
To explicitly configure the default values on each peer switch, use the unit-id command.
Configure a different unit ID (0 or 1) on each peer switch.
Unit IDs are used for internal system operations.
Use this command to minimize the time required for the VLT system to determine the unit ID assigned
to each peer switch when one peer switch reboots.
Virtual Link Trunking (VLT) 1134

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4048T and is the answer not in the manual?

Dell S4048T Specifications

General IconGeneral
Switching Capacity1.44 Tbps
Rack Units1U
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyOptional
Product TypeSwitch
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, VRRP, PIM-SM, IGMP
Remote Management ProtocolSNMP, RMON, Telnet, SSH
FeaturesQuality of Service (QoS), Jumbo Frames Support, Virtual Route Redundancy Protocol (VRRP), VLAN support, sFlow, Multiple Spanning Tree Protocol (MSTP), Rapid Spanning Tree Protocol (RSTP), IPv6 support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ae
Dimensions (W x D x H)17.3 in x 16 in x 1.7 in
Operating Temperature0°C to 40 °C
Operating Humidity10% to 90% (non-condensing)

Related product manuals