EasyManuals Logo

Dell S4048T User Manual

Dell S4048T
1277 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #423 background imageLoading...
Page #423 background image
Software Resiliency
During normal operations, Dell Networking OS monitors the health of both hardware and software
components in the background to identify potential failures, even before these failures manifest.
Software Component Health Monitoring
On each of the line cards and the stack unit, there are a number of software components. Dell Networking
OS performs a periodic health check on each of these components by querying the status of a flag, which the
corresponding component resets within a specified time.
If any health checks on the stack unit fail, the Dell Networking OS fails over to standby stack unit. If any health
checks on a line card fail, Dell Networking OS resets the card to bring it back to the correct state.
System Health Monitoring
Dell Networking OS also monitors the overall health of the system.
Key parameters such as CPU utilization, free memory, and error counters (for example, CRC failures and
packet loss) are measured, and after exceeding a threshold can be used to initiate recovery mechanism.
Failure and Event Logging
Dell Networking systems provide multiple options for logging failures and events.
Trace Log
Developers interlace messages with software code to track the execution of a program.
These messages are called trace messages and are primarily used for debugging and to provide lower-level
information then event messages, which system administrators primarily use. Dell Networking OS retains
executed trace messages for hardware and software and stores them in files (logs) on the internal flash.
NV Trace Log — contains line card bootup trace messages that Dell Networking OS never overwrites
and is stored in internal flash under the directory NVTRACE_LOG_DIR.
Trace Log — contains trace messages related to software and hardware events, state, and errors. Trace
Logs are stored in internal flash under the directory TRACE_LOG_DIR.
Crash Log — contains trace messages related to IPC and IRC timeouts and task crashes on line cards
and is stored under the directory CRASH_LOG_DIR.
For more information about trace logs and configuration options, refer to
S-Series Debugging and Diagnostics.
High Availability (HA) 423

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4048T and is the answer not in the manual?

Dell S4048T Specifications

General IconGeneral
Switching Capacity1.44 Tbps
Rack Units1U
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyOptional
Product TypeSwitch
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, VRRP, PIM-SM, IGMP
Remote Management ProtocolSNMP, RMON, Telnet, SSH
FeaturesQuality of Service (QoS), Jumbo Frames Support, Virtual Route Redundancy Protocol (VRRP), VLAN support, sFlow, Multiple Spanning Tree Protocol (MSTP), Rapid Spanning Tree Protocol (RSTP), IPv6 support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ae
Dimensions (W x D x H)17.3 in x 16 in x 1.7 in
Operating Temperature0°C to 40 °C
Operating Humidity10% to 90% (non-condensing)