The following example shows the show vxlan vxlan-instance unicast-mac-local command.
Dell# show vxlan vxlan-instance <1> unicast-mac-local
Total Local Mac Count: 5
VNI MAC PORT VLAN
4656 00:00:02:00:03:00 Te 0/17 0
4656 00:00:02:00:03:01 Te 0/17 0
4656 00:00:02:00:03:02 Te 0/17 0
4656 00:00:02:00:03:03 Te 0/17 0
4656 00:00:02:00:03:04 Te 0/17 0
The following example shows the show vxlan vxlan-instance unicast-mac-remote command.
Dell# show vxlan vxlan-instance <1> unicast-mac-remote
Total Local Mac Count: 1
VNI MAC TUNNEL
4656 00:00:01:00:00:01 36.1.1.1
VXLAN Service nodes for BFD
When multiple service nodes are available for a given Logical Network, Network Virtualization Overlay (NVO)
gateway picks one of the service nodes for forwarding Broadcast unknown Unicast and Multicast Traffic
(BUM). When one of the service nodes goes down or bfd is down in that service node, the gateway switches
to the alternate service node for Broadcast unknown Unicast and Multicast Traffic (BUM).
Examples of the show bfd neighbors command.
To verify that the session is established, use the show bfd neighbors command.
Dell_GW1#show bfd neighbors
* - Active session role
Ad Dn - Admin Down
B - BGP
C - CLI
I - ISIS
O - OSPF
O3 - OSPFv3
R - Static Route (RTM)
M - MPLS
V - VRRP
VT - Vxlan Tunnel
LocalAddr RemoteAddr Interface State Rx-int Tx-int Mult Clients
* 1.0.1.1 1.0.1.2 Te 1/49/1 Up 200 200 3 B
* 3.3.3.3 192.168.122.135 Te 1/38 Up 1000 1000 3 VT
* 3.3.3.3 192.168.122.136 Te 1/42 Up 1000 1000 3 VT
* 3.3.3.3 192.168.122.137 Te 1/43 Up 1000 1000 3 VT
* 3.3.3.3 192.168.122.138 Te 1/38 Up 1000 1000 3 VT
* 3.3.3.3 192.168.122.139 Te 1/42 Up 1000 1000 3 VT
Virtual Extensible LAN (VXLAN) 1185

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell S4048T and is the answer not in the manual?

Dell S4048T Specifications

General IconGeneral
Switching Capacity1.44 Tbps
Rack Units1U
Form FactorRack-mountable
Power DeviceInternal power supply
Power RedundancyOptional
Product TypeSwitch
Jumbo Frame SupportYes
Routing ProtocolOSPF, BGP, RIP, VRRP, PIM-SM, IGMP
Remote Management ProtocolSNMP, RMON, Telnet, SSH
FeaturesQuality of Service (QoS), Jumbo Frames Support, Virtual Route Redundancy Protocol (VRRP), VLAN support, sFlow, Multiple Spanning Tree Protocol (MSTP), Rapid Spanning Tree Protocol (RSTP), IPv6 support
Compliant StandardsIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3ae
Dimensions (W x D x H)17.3 in x 16 in x 1.7 in
Operating Temperature0°C to 40 °C
Operating Humidity10% to 90% (non-condensing)