Maintenance 4. Cable
168 N6 Rev.2
C
able A
Set the A4 of the cable tie to the cable
fixing plate and fix it with by using the
cable ties 1 and 2. Make sure to twist
180 degrees and fix the cable A so that the
gray colored cable is on the opposite side
of the plate.
C
able B
Set the B4 of the cable tie to the cable
fixing plate and fix it by using the cable
ties 3 and 4. Make sure to twist 180
degrees and fix the cable B so that the two
air tubes (blue and white) are on the plate
side.
A
End effector side
Front
B
Refer to the figure for positions of the cable
tie heads.
Rotate the heads of the cable ties A4 and B4
to set positions.
Be careful for the orders and the positions of
the cable ties.
Distance between the cable tie 1 and A4, and 3
and B4 should be as close as possible.
A
End effector side
B
Back
1
3
A4
B4
2
4
Improper order or position of the cable tie may shorten the life cycle of the cables.
(14)
Apply the grease to the cables between the
two cable fixing plates.
Grease:
Krytox: Cable A and B
Standard model : 1g for each
Cleanroom model : 1.5g for each
Apply the grease to each cable evenly.
Grease application range
(15)
Install the cable fixing plates to Arm #1.
Hexagon socket head cap bolts: 2-M4×8
Tightening torque: 4.0 ± 0.2 N·m
Be careful not to tighten the screws with the
cables get caught on the plate
.
NOTE