5.2 Function Codes Table
5-7
FUNCTION CODES
Chap 5
E code: Extension Terminal Functions (Terminal function)
Code
Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V
/f
PG
V/f
w/ PG
Torque control
PM
E01
Terminal [X1] function
0 (1000): Select multistep frequency (0 to 1 steps) “SS1”
N
Y
0
Y
Y
Y
N
Y
5-100
E02
Terminal [X2] function
1 (1001): Select multistep frequency (0 to 3 steps) “SS2”
N
Y
1
Y
Y
Y
N
Y
E03
Terminal [X3] function
2 (1002): Select multistep frequency (0 to 7 steps) “SS4”
N
Y
2
Y
Y
Y
N
Y
E04
Terminal [X4] function
3 (1003): Select multistep frequency (0 to 15 steps) “SS8”
N
Y
7
Y
Y
Y
N
Y
E05
Terminal [X5] function
4 (1004): Select ACC/DEC time (2 steps) RT1
N
Y
8
Y
Y
Y
N
Y
5 (1005): Select ACC/DEC time (4 steps) RT2
Y
Y
Y
N
Y
6 (1006): Select 3-wire operation HLD
Y
Y
Y
N
Y
7 (1007): Coast to a stop command BX
Y
Y
Y
Y
Y
8 (1008): Reset alarm (Abnormal) RST
Y
Y
Y
Y
Y
9 (1009): External alarm THR
(9 = Active OFF/ 1009 = Active ON)
Y
Y
Y
Y
Y
10 (1010): Ready for jogging “JOG”
Y
Y
Y
N
N
11 (1011): Select frequency setting 2/ frequency setting 1
Hz2/ Hz1
Y
Y
Y
N
Y
12 (1012): Select motor 2 M2
Y
Y
Y
Y
Y
13: DC braking command DCBRK
Y
Y
Y
N
N
14 (1014): Select torque limit 2/ torque limit 1
TL2/ TL1
Y
Y
Y
Y
Y
15: Switch to commercial power (50 Hz) SW50
Y
Y
N
N
N
16: Switch to commercial power (60 Hz) SW60
Y
Y
N
N
N
17 (1017): UP command UP
Y
Y
Y
N
Y
18 (1018): DOWN command DOWN
Y
Y
Y
N
Y
19 (1019): Allow function code editing
(Data change enabled) WE-KP”
Y
Y
Y
Y
Y
20 (1020): Cancel PID control Hz/PID
Y
Y
Y
N
Y
21 (1021): Switch normal/ inverse operation “IVS”
Y
Y
Y
N
Y
22 (1022): Interlock IL
Y
Y
Y
Y
Y
23 (1023): Cancel torque control *5 Hz/TRQ
N
N
N
Y
N
24 (1024): Select link operation (RS-485, BUS option) LE
Y
Y
Y
Y
Y
25 (1025): Universal DI “U-DI
Y
Y
Y
Y
Y
26 (1026): Select auto search for idling motor speed at
starting STM
Y
Y
N
N
Y
30 (1030): Force to stop “STOP”
(30 = Active OFF/1030 = Active ON)
Y
Y
Y
Y
Y
32 (1032): Pre-excite *5 EXITE
N
N
Y
Y
N
33 (1033): Reset PID integral and differential terms
“PID-RST
Y
Y
Y
N
Y
34 (1034): Hold PID integral term “PID-HLD
Y
Y
Y
N
Y
35 (1035): Select local (Keypad) command LOC
Y
Y
Y
Y
Y
42 (1042): Activate the limit switch at start point *5 LS
Y
Y
N
N
N
43 (1043): Start / Reset *5 “S/R”
Y
Y
N
N
N
44 (1044): Switch to the serial pulse receiving mode *5
“SPRM”
Y
Y
N
N
N
45 (1045): Enter the return mode *5 RTN
Y
Y
N
N
N
46 (1046): Enable overload stop OLS
Y
Y
Y
N
Y
47 (1047): Servo lock command *5 LOCK
N
N
Y
N
N
48: Pulse train input (Only for X5 terminal (E05))
“PIN”
Y
Y
Y
N
Y
49 (1049): Pulse train sign “SIGN”
(Other than X5 terminal (E01 to E04))
Y
Y
Y
N
Y
59 (1059): Enable battery-driven operation *11
“BATRY/UPS”
Y
Y
Y
N
N
60 (1060): Select torque bias1 *5 “TB1”
N
N
Y
N
N
61 (1061): Select torque bias2 *5 “TB2”
N
N
Y
N
N
62 (1062): Hold torque bias *5 “H-TB”
N
N
Y
N
N
65 (1065): Check brake “BRKE”
Y
Y
Y
N
N
70 (1070): Cancel line speed control *5 “Hz/LSC”
Y
Y
Y
N
N
*5: Available at ROM version 0300 or later.