5.2 Function Codes Table
5-8
Code
Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V
/f
PG
V/f
w/ PG
Torque control
PM
71 (1071): Hold line speed control frequency in the memory
*5 “LSC-HLD”
Y
Y
Y
N
N
72 (1072): Count the run time of commercial power-driven
motor 1 *5 CRUN-M1
Y
Y
Y
Y
N
73 (1073): Count the run time of commercial power-driven
motor 2 *5 CRUN-M2
Y
Y
Y
Y
N
76 (1076): Select droop control DROOP
Y
Y
Y
N
N
78 (1078): Select speed control parameter 1 *5 MPRM1
N
Y
Y
Y
Y
79 (1079): Select speed control parameter 2 *5 MPRM2
N
Y
Y
Y
Y
80 (1080): Cancel customizable logic CLC
Y
Y
Y
Y
Y
81 (1081): Clear all customizable logic timers CLTC
Y
Y
Y
Y
Y
82 (1082): Cancel anti-regenerative control “AR-CCL
Y
Y
Y
N
Y
100: No function assigned NONE
Y
Y
Y
Y
Y
171 (1171): PID control multistage command 1 “PID-SS1”
Y
Y
Y
N
Y
172 (1172): PID control multistage command 2 “PID-SS2”
Y
Y
Y
N
Y
* Inside the ( ) is the negative logic signal (OFF at
short-circuit)
E10
Acceleration time2
0.00 to 6000 s
* 0.00 is for acceleration and deceleration time cancel
(when performing soft-start and stop externally)
Y
Y
6.00
or
20.0
*10
Y
Y
Y
N
Y
5-116
E11
Deceleration time2
Y
Y
Y
Y
Y
N
Y
E12
Acceleration time 3
Y
Y
Y
Y
Y
N
Y
E13
Deceleration time 3
Y
Y
Y
Y
Y
N
Y
E14
Acceleration time 4
Y
Y
Y
Y
Y
N
Y
E15
Deceleration time 4
Y
Y
Y
Y
Y
N
Y
E16
Torque limiter 2 (Driving)
0 to 300%; 999 (Disable)
Y
Y
999
Y
Y
Y
Y
Y
5-116
E17
(Braking)
0 to 300%; 999 (Disable)
Y
Y
999
Y
Y
Y
Y
Y
E20
Terminal [Y1] function
0 (1000): Inverter running RUN
N
Y
0
Y
Y
Y
Y
Y
5-117
E21
Terminal [Y2] function
1 (1001): Frequency (speed) arrival FAR
N
Y
7
Y
Y
Y
N
Y
E27
Terminal [30A/B/C] function
(Relay output)
2 (1002): Frequency (speed) detected FDT
N
Y
99
Y
Y
Y
Y
Y
3 (1003): Under voltage detected (inverter stopped) LU
Y
Y
Y
Y
Y
4 (1004): Detected torque polarity “B/D”
Y
Y
Y
Y
Y
5 (1005): Inverter output limiting “IOL”
Y
Y
Y
Y
Y
6 (1006): Auto-restarting after momentary power failure
“IPF”
Y
Y
Y
Y
Y
7 (1007): Motor overload early warning “OL”
Y
Y
Y
Y
Y
8 (1008): Keypad operation enabled “KP”
Y
Y
Y
Y
Y
10 (1010): Inverter ready to run RDY
Y
Y
Y
Y
Y
15 (1015): Switch MC on the input power lines AX
Y
Y
Y
Y
Y
16 (1016): Pattern operation stage transition “TU”
Y
Y
Y
N
Y
17 (1017): Pattern operation cycle completed “TO”
Y
Y
Y
N
Y
18 (1018): Pattern operation stage 1 “STG1”
Y
Y
Y
N
Y
19 (1019): Pattern operation stage 2 “STG2”
Y
Y
Y
N
Y
20 (1020): Pattern operation stage 4 “STG4”
Y
Y
Y
N
Y
21 (1021): Frequency (speed) arrival 2 “FAR2”
Y
Y
Y
N
Y
22 (1022): Inverter output limiting with delay “IOL2”
Y
Y
Y
Y
Y
25 (1025): Cooling fan in operation “FAN”
Y
Y
Y
Y
Y
26 (1026): Auto-resetting “TRY”
Y
Y
Y
Y
Y
27 (1027): Universal DO “U-DO”
Y
Y
Y
Y
Y
28 (1028): Heat sink overheat early warning “OH”
Y
Y
Y
Y
Y
29 (1029): Synchronization completed *5 “SY”
N
Y
Y
N
N
30 (1030): Lifetime alarm “LIFE”
Y
Y
Y
Y
Y
31 (1031): Frequency (speed) detected 2 “FDT2”
Y
Y
Y
Y
Y
33 (1033): Reference loss detected REF OFF”
Y
Y
Y
N
Y
35 (1035): Inverter outputting “RUN 2”
Y
Y
Y
Y
Y
36 (1036): Overload prevention controlling “OLP”
Y
Y
Y
N
Y
37 (1037): Current detected “ID”
Y
Y
Y
Y
Y
38 (1038): Current detected 2 “ID2”
Y
Y
Y
Y
Y
39 (1039): Current detected 3 “ID3”
Y
Y
Y
Y
Y
*5: Available at ROM version 0300 or later.