Page #121 background image
RX100 S8
Upgrade and Maintenance Manual 121
Hard disk drives / solid state drives
In order to permanently remove an operational HDD module that is part of a
RAID array from the server, you first need to delete the array using
ServerView RAID Manager.
V CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
7.2.6.2 Removing a 2.5-inch HDD/SSD module
Ê Pinch the green locking clips and open the locking lever (see figure 53).
Ê Pull the HDD/SSD module out a few centimeters.
Ê Wait about 30 seconds to allow the hard disk drive to spin down.
I This is not necessary when removing a solid state drive.
I This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê Pull the HDD/SSD module completely out of its bay.
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section "Performing a RAID array
rebuild" on page 85.
RAID level Procedure

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX100 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX100 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX100 S8
CategoryServer
LanguageEnglish

Related product manuals