RX100 S8
Upgrade and Maintenance Manual 123
Hard disk drives / solid state drives
Under no circumstances should you remove an HDD/SSD module
while the system is in operation if you are not sure that the drive is
operated by a RAID controller and belongs to a disk array that is
operating in RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD/SSD module can only be replaced during operation in
conjunction with a corresponding RAID configuration.
All HDD/SSD modules (drives) must be uniquely identified so that
they can be reinstalled in their original bays later. If this is not done,
existing data can be lost.
7.2.7.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê "Locating the defective component" on page 45
Only applicable for removing intact HDD/SSD modules:
Ê Before removing a non-defective HDD/SSD module, put the drive into
"Offline" mode using your RAID configuration software.
7.2.7.2 Removing the defective 2.5-inch HDD/SSD module
Ê Remove the HDD/SSD module as described in section "Removing 2.5-inch
HDD/SSD modules" on page 120.
7.2.7.3 Installing the new 2.5-inch HDD/SSD module
Ê Install the HDD/SSD module as described in section "Installing 2.5-inch
HDD/SSD modules" on page 118.
7.2.7.4 Concluding steps
Ê "Performing a RAID array rebuild" on page 85

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX100 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX100 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX100 S8
CategoryServer
LanguageEnglish

Related product manuals