RX100 S8
Upgrade and Maintenance Manual 257
System board and components
Ê Save your changes and exit the BIOS.
I For detailed information on how to access the BIOS and modify
settings, refer to the corresponding BIOS Setup Utility reference
manual.
14.4.2 Removing the TPM
V CAUTION!
Advise your contact persons that they must provide you with TPM
backup copies. For security reasons, the TPM must be restored/re-
saved by the customer. After installing a new system board, the TPM
must be enabled. You may not clear the TPM data.
If the contact persons DO NOT have a backup copy available, inform
them that removing the TPM will cause to lose all data.
14.4.2.1 Preliminary steps
Before removing the TPM board, perform the following steps:
Ê Before removing the TPM board, it is necessary to remove BitLocker-
protection from the computer and to decrypt the volume.
Ask the system administrator to turn off BitLocker-protection using the
BitLocker setup wizard available either from the Control Panel or Windows
Explorer:
Field Replaceable Unit
(FRU)
Hardware: 30 minutes
Tools: Removing the system board:
– Phillips PH2 / (+) No. 2 screw driver
Removing the TPM:
– Bit screw driver
– flat nose pliers
– TPM bit insert
(
*
)
(
*
)
For the Japanese market:
– TPM module fixing tool (S26361-F3552-L909)

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX100 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX100 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX100 S8
CategoryServer
LanguageEnglish

Related product manuals