EasyManua.ls Logo

Fujitsu PRIMERGY RX100 S8 - Replacing the 10 X 2.5-Inch HDD Backplane; Preliminary Steps; Removing the SAS Expander Board

Fujitsu PRIMERGY RX100 S8
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
130 Upgrade and Maintenance Manual
RX100 S8
Hard disk drives / solid state drives
7.2.9 Replacing the 10 x 2.5-inch HDD backplane
7.2.9.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê "Shutting down the server" on page 45
Ê "Disconnecting the server from the mains" on page 46
Ê "Getting access to the component" on page 47
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section "Removing 2.5-inch HDD/SSD modules" on page 120
I The HDD/SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all HDD/SSD modules are
uniquely identified so that you can reinsert them into their original
bays.
7.2.9.2 Removing the SAS expander board
Figure 62: Disconnecting power cable from the HDD backplane
Ê Disconnect the power cable from the HDD backplane.
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Tools: Phillips PH2 / (+) No. 2 screw driver (for removing/installing SAS
expander board)

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S8

Related product manuals