RX100 S8
Upgrade and Maintenance Manual 265
System board and components
14.5.1.1 Preliminary steps
Ê "Locating the defective server" on page 43
Ê "Note on network settings recovery" on page 264
Ê "Disabling SVOM boot watchdog functionality" on page 64
Ê "Disabling BitLocker functionality" on page 63
Ê "Shutting down the server" on page 45
Ê "Disconnecting the server from the mains" on page 46
Ê Disconnect all external cables.
Ê "Getting access to the component" on page 47
Ê Remove all memory modules, see section "Removing a memory module" on
page 209.
I Before removing the memory modules, take a note on the installation
slot number for each memory module. Make sure that you reinstall
the memory modules in the slot they were located before the
replacement.
Ê Remove the heat sink, see section "Removing the heat sink" on page 213.
Ê Remove all expansion cards, see section "Expansion cards and riser cards"
on page 171.
I Before removing the expansion cards, take a note on the installation
slot number for each card. Make sure that you reinstall the card in the
slot it was located before the replacement.
Ê Remove the UFM (if applicable), see section "Removing the defective UFM"
on page 251.
I Remove the UFM spacer from the defective system board and fasten
it with the UFM screw to the UFM board.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX100 S8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX100 S8 and is the answer not in the manual?

Fujitsu PRIMERGY RX100 S8 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX100 S8
CategoryServer
LanguageEnglish

Related product manuals