Overview
TABLE 2-1 7200 ACS SPECIFICATIONS
Environmental
Antenna Control Rack-mounted Unit:
Temperature - 0°C to + 50°C; Humidity - 90% non-condensing
Drive Cabinet:
Temperature (Standard) -10°C to +50°C
Temperature (Optional) -40°C to +50°C (Low temperature package)
Humidity - 100% condensing.
Specifications subject to change without notice.
2.3 System Configuration
Refer to Figure 2-1 for a typical overall block diagram of the integrated control
system. Items shown with solid interconnection lines represent fundamental
system components that provide automatic positioning for a two-axis system.
Items connected with a dashed line represent typical system options such as a
tracking receiver, POL motorization components, Customer-Furnished Equipment
(CFE), and remote Monitor and Control (M&C) equipment.
Figure 2-1 Typical 7200 ACS Block Diagram
2-3