7200 PASSWORD PROTECTION
B - 1
APPENDIX B - 7200 ACU PASSWORD PROTECTION
This appendix details the usage of the password protection system on the 7200.
Procedures are provided for setting and changing the password. Procedures are
also provided for clearing the password, if the user has forgotten the password or
the user does not want password protection to be enabled on the system at any
time.
The 7200 ACU, as shipped, has password protection enabled with all passwords
cleared. The user can then set the password by entering the Set user level (and
passwords)... menu and following the procedures provided in paragraph 5.8.4 in
the Operations Section of this manual.
If the passwords have already been set, the ACU will ask for the old password first
before accepting a new password.
If a password has been lost or the user wants to disable password protection, use
the following procedures to reset a password or disable password protection.
The following tools are required:
1 flathead screwdriver for #10-32 screws
1 Phillips screwdriver for #6-32 screws
1 trimming tool or small flathead screwdriver
1. On the front of the 7200 ACU, set the DRIVE ENABLE switch to disable the
drives.
2. Using a large flathead screwdriver, remove the four screws holding the 7200
ACU in the rack.
3. On the rear of the 7200 ACU, set the power switch to the off position.
4. On the rear of the 7200 ACU, check that all cables have enough slack to
allow the unit to be pulled forward about 20 inches (50 centimeters).
5. Carefully slide the 7200 ACU forward until the hinge at the rear of the top
cover clears the front of the rack.
6. Using a Phillips screwdriver, remove the two screws holding the front of the
cover.