SITE TEST PROCEDURE
F - 11
12. Record the EL angle at which the limit occurred. ______(Record)
13. Drive the antenna down in EL to check that the antenna
will back out of the soft limit. _______(Check)
14. Drive the antenna down in EL until the soft limit stops the
movement of the antenna. _______(Check)
15. Check the display for a SOFT LIMIT message. _______(Check)
16. Record the EL angle at which the limit occurred. ______(Record)
17. Drive the antenna up in EL to check that the antenna will
back out of the soft limit. _______(Check)
THREE AXIS SYSTEM
18. Drive the feed tube CCW until the soft limit stops the
movement of the feed tube. _______(Check)
19. Check the display for a SOFT LIMIT message. _______(Check)
20. Record the POL angle at which the limit occurred. ______(Record)
21. Drive the feed tube CW to check that the feed tube will
back out of the soft limit. _______(Check)
22. Drive the feed tube CW until the soft limit stops the
movement of the feed tube. _______(Check)
23. Check the display for a SOFT LIMIT message. _______(Check)
24. Record the POL angle at which the limit occurred. ______(Record)
25. Drive the feed tube CCW to check that the feed tube will
back out of the soft limit. _______(Check)