Installation
5. Slide the 7200 ACU into the rack-mounted slides.
6. Adjust the rack-mounted slides as necessary until the ACU slides smoothly in and out
of the rack.
7. Fully tighten all hardware.
8. There is a stud on the rear panel of the 7200 ACU that is marked with the protective
earth (ground) symbol. A proper grounding wire from the rack that this piece of
equipment is installed into should be attached to this stud, making sure that the end of
the grounding wire has good metal-to-metal contact with the rear panel of the ACU.
Use the hex nut provided with the ACU (or similar nut) to secure this grounding wire to
the rear panel stud.
9. Make sure the area directly behind the fan on the rear panel of the 7200 ACU is kept
clear once the equipment is installed in the rack to allow for proper ventilation of the
unit.
10. The 7200 ACU should be connected to a grounded AC power outlet using a detachable
power cord.
4-3