EasyManua.ls Logo

Hioki 3153 - Page 197

Hioki 3153
255 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
184
_____________________________________________________________________________________________
10.3 RS-232C Command Reference
______________________________________________________________________________________________
Syntax
:MEASure:WITHstand:CURRent?
Response
syntax
<data>
<data>
Withstand-voltage test measured current value (NR1 or NR2)
Function
Queries the measured current value (unit: mA) for withstand-voltage tests.
Example
Queries the measured current value for withstand-voltage tests.
Transmission :MEASure:WITHstand:CURRent?
Response 2.00
The measured current value is 2.00 mA.
Error
The execution of this command in a state other than the TEST state causes an execution error.
Syntax
:MEASure:WITHstand:TIMer?
Response
syntax
<data1>, <data2>
<data1>
Withstand-voltage test time elapsed (NR1 or NR2)
<data2>
Timer types:
0
(test time),
1
(ramp-up time),
2
(ramp-down time) (NR1)
Function
Queries the test time elapsed (unit: s) for withstand-voltage tests.
Example
Queries the test time elapsed for withstand-voltage tests.
Transmission :MEASure:WITHstand:TIMer?
Response 30.0,0
The elapsed test time is 30.0 s, and the type of timer is test time.
Error
The execution of this command in a state other than the TEST state causes an execution error.
:MEASure:WITHstand:CURRent?
Queries the measured current value for withstand-voltage tests.
:MEASure:WITHstand:TIMer?
Queries the test time elapsed for withstand-voltage tests.