EasyManua.ls Logo

Juniper EX4300

Juniper EX4300
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION: The AC power cord for the EX4300 switch is intended for use with
this switch only. Do not use the cord with any other product.
CAUTION: Power cords must not block access to switch components.
Related
Documentation
AC Power Supply in EX4300 Switches on page 49
General Safety Guidelines and Warnings on page 283
General Electrical Safety Guidelines and Warnings on page 311
Prevention of Electrostatic Discharge Damage on page 313
Connecting AC Power to an EX4300 Switch on page 185
DC Power Supply Specifications for EX4300 Switches
Table 67 on page 104 lists the power supply specifications for a DC power supply used in
an EX4300 switch.
Table 67: DC Power Supply Specifications for an EX4300 Switch
SpecificationsItem
Nominal operating voltage: –48 VDC
Operating voltage range: –48 VDC through –60 VDC
DC input voltage
4 A maximum at nominal operating voltage (–48 VDC)DC input current rating
550 WOutput power
Related
Documentation
DC Power Supply in EX4300 Switches on page 57
DC Power Supply LEDs in EX4300 Switches on page 62
Calculating the EX Series Switch Fiber-Optic Cable Power Budget
Calculate the link's power budget when planning fiber-optic cable layout and distances
to ensure that fiber-optic connections have sufficient power for correct operation. The
power budget is the maximum amount of power the link can transmit. When you calculate
the power budget, you use a worst-case analysis to provide a margin of error, even though
all the parts of an actual system do not operate at the worst-case levels.
Copyright © 2017, Juniper Networks, Inc.104