Table 27: Details of the AC Power Supplies in EX4300 Switches (continued)
1100 W AC Power Supply715 W AC Power Supply350 W AC Power SupplyDetails
Front-to-back, indicated by
label AIR OUT (AFO)
Front-to-back, indicated by
label AIR OUT (AFO)
Front-to-back, indicated
by label AIR OUT (AFO)
Back-to-front, indicated
by label AIR IN (AFI)
Airflow
111AC power cord retainer
IN OK and OUT OKIN OK and OUT OKIN OK and OUT OKPower supply status LEDs
115–240 VAC100–240 VAC100–240 VACOperating range
To prevent electrical injury while installing or removing AC power supplies, carefully follow
instructions in “Installing an AC Power Supply in an EX4300 Switch” on page 233 and
“Removing an AC Power Supply from an EX4300 Switch” on page 235.
AC Power Supply Airflow
Each power supply has its own fan and is cooled by its own internal cooling system.
Each power supply has a label AIR OUT (AFO) or AIR IN (AFI) on the faceplate of the
power supply that indicates the direction of airflow in the power supply.
Table 28 on page 51 lists the AC power supply models and the direction of airflow in
them.
Table 28: Airflow Direction in AC Power Supply Models for EX4300 Switches
Direction of Airflow
Label on Power
SupplyModel
Front-to-back—that is, air intake to cool the chassis is through the vents
on the front panel of the chassis and hot air exhausts through the vents
on the rear panel of the chassis.
AIR OUT (AFO)JPSU-350-AC-AFO-A
Back-to-front—that is, air intake to cool the chassis is through the vents
on the rear panel of the chassis and hot air exhausts through the vents on
the front panel of the chassis.
AIR IN (AFI)JPSU-350-AC-AFI-A
Front-to-back—that is, air intake to cool the chassis is through the vents
on the front panel of the chassis and hot air exhausts through the vents
on the rear panel of the chassis.
AIR OUT (AFO)JPSU-715-AC-AFO-A
Front-to-back—that is, air intake to cool the chassis is through the vents
on the front panel of the chassis and hot air exhausts through the vents
on the rear panel of the chassis.
AIR OUT (AFO)JPSU-1100-AC-AFO-A
51Copyright © 2017, Juniper Networks, Inc.
Chapter 4: Power Supplies

Table of Contents

Other manuals for Juniper EX4300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 and is the answer not in the manual?

Juniper EX4300 Specifications

General IconGeneral
ModelEX4300
Virtual ChassisYes, up to 10 members
Layer 3 RoutingYes
10GBASE SFP+ Ports4
Jumbo Frames9216 bytes
MAC Address Table Size32, 000
Operating SystemJunos OS
Uplink Ports4 x 10GBASE SFP+
Power SupplyAC or DC options
Operating Temperature0°C to 45°C (32°F to 113°F)
Input Voltage100-240V AC
Operating Relative Humidity5 to 90% RH, non-condensing
Management OptionsCLI, Web UI, Junos Space
RedundancyYes, power supply and fans
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Ports24 or 48