Warnung Der Erdanschl muß bei der Installation der Einheit immer zuerst
hergestellt und zuletzt abgetrennt werden.
Avvertenza In fase di installazione dell'unità, eseguire sempre per primo il
collegamento a massa e disconnetterlo per ultimo.
Advarsel Når enheten installeres, jordledningen alltid tilkobles først og
frakobles sist.
Aviso Ao instalar a unidade, a ligação à terra deverá ser sempre a primeira a
ser ligada, e a última a ser desligada.
¡Atención! Al instalar el equipo, conectar la tierra la primera y desconectarla
la última.
Varning! Vid installation av enheten måste jordledningen alltid anslutas först
och kopplas bort sist.
Related
Documentation
General Safety Guidelines and Warnings on page 283
General Electrical Safety Guidelines and Warnings on page 311
DC Power Electrical Safety Guidelines for Switches on page 316
DC Power Disconnection Warning on page 319
DC Power Wiring Sequence Warning on page 321
DC Power Wiring Terminations Warning on page 323
DC Power Wiring Sequence Warning
WARNING: Wire the DC power supply using the appropriate lugs. When
connecting power, the proper wiring sequence is ground to ground, +RTN to
+RTN, then –48 V to –48 V. When disconnecting power, the proper wiring
sequence is –48 V to –48 V, +RTN to +RTN, then ground to ground. Note
that the ground wire must always be connected first and disconnected last.
Waarschuwing De juiste bedradingsvolgorde verbonden is aarde naar aarde,
+RTN naar +RTN, en –48 V naar 48 V. De juiste bedradingsvolgorde
losgemaakt is en –48 naar –48 V, +RTN naar +RTN, aarde naar aarde.
Varoitus Oikea yhdistettava kytkentajarjestys on maajohto maajohtoon,
+RTN varten +RTN, –48 V varten 48 V. Oikea irrotettava kytkentajarjestys
on –48 V varten 48 V, +RTN varten +RTN, maajohto maajohtoon.
Attention Câblez l'approvisionnement d'alimentation CC En utilisant les
crochets appropriés à l'extrémité de câblage. En reliant la puissance, l'ordre
approprié de câblage est rectifié pour rectifier, +RTN à +RTN, puis –48 V à
321Copyright © 2017, Juniper Networks, Inc.
Chapter 27: Electrical Safety Guidelines and Warnings

Table of Contents

Other manuals for Juniper EX4300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Juniper EX4300 and is the answer not in the manual?

Juniper EX4300 Specifications

General IconGeneral
ModelEX4300
Virtual ChassisYes, up to 10 members
Layer 3 RoutingYes
10GBASE SFP+ Ports4
Jumbo Frames9216 bytes
MAC Address Table Size32, 000
Operating SystemJunos OS
Uplink Ports4 x 10GBASE SFP+
Power SupplyAC or DC options
Operating Temperature0°C to 45°C (32°F to 113°F)
Input Voltage100-240V AC
Operating Relative Humidity5 to 90% RH, non-condensing
Management OptionsCLI, Web UI, Junos Space
RedundancyYes, power supply and fans
Storage Temperature-40°F to 158°F (-40°C to 70°C)
Ports24 or 48

Related product manuals