Table 58 on page 89 provides the required environmental conditions for normal switch
operation.
Table 58: EX Series Switch Environmental Tolerances
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 104° F (40° C) at
altitudes up to 5,000 ft
(1,524 m).
For informationabout extended
temperature SFP transceivers
supportedon EX2200 switches,
see Pluggable Transceivers
Supported on EX2200 Switches.
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet
(1524 meters)
EX2200-C
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX2200
(except
EX2200-C
switches)
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 104° F (40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
5,000 feet
(1524 meters)
EX2300-C
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
13,000 feet
(3962.4 meters) at
104° F (40° C) as per
GR-63
EX2300
(except
EX2300-C
switches)
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX3200
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX3300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX3400
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4200
89Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Preparation Overview