EasyManua.ls Logo

Juniper EX4300

Juniper EX4300
354 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 58: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4300
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 32° F (0° C)
through 113° F (45° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4500
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
EX4550-32F
switches—Normal operation
ensured in the temperature
range 32° F (0° C) through
113° F (45° C)
EX4550-32T
switches—Normal operation
is ensuredin the temperature
range 32° F through 104° F
(40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX4550
Designed to comply
with Zone 4
earthquake
requirements per
NEBS GR-63-CORE,
Issue 4.
Normal operation ensured in
the temperature range 32° F
(0° C) through 113° F (45° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operationensuredin
the relative humidity range
5% through 90%,
noncondensing
Short-term operation
ensured in the relative
humidity range 5%
through 93%,
noncondensing
NOTE: As defined in
NEBS GR-63-CORE, Issue
4, short-term events can
be up to 96 hours in
duration but not more
than 15 days per year.
No performance
degradation to
6,562 feet
(2000 meters)
EX4600
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX6210
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8208