Table 58: EX Series Switch Environmental Tolerances (continued)
Environment Tolerance
Switch or
device SeismicTemperatureRelative HumidityAltitude
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX8216
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensuredin
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9204
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C) to
158° F (70° C)
Normal operationensuredin
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9208
Complies with Zone 4
earthquake
requirements as per
GR-63.
Normal operation is ensured in
the temperature range 32° F
(0° C) through 104° F (40° C)
Nonoperating storage
temperature in shipping
container: –40° F (–40° C)
through 158° F (70° C)
Normal operationensuredin
the relative humidity range
5% through 90%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
EX9214
Complies with Zone 4
earthquake
requirements as per
GR-63, Issue 4.
Normal operationensuredin the
temperature range 41° F (5° C)
through 104° F (40° C)
Normal operationensuredin
the relative humidity range
10% through 85%
(noncondensing)
No performance
degradation up to
10,000 feet
(3048 meters)
XRE200
NOTE: Install EX Series switches only in restricted areas, such as dedicated
equipment roomsand equipment closets, in accordancewith Articles110–16,
110–17, and 110–18 of the National Electrical Code, ANSI/NFPA 70.
Related
Documentation
Clearance Requirements for Airflow and Hardware Maintenance for EX2200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX2300 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3200 Switches
Clearance Requirements for Airflow and Hardware Maintenance for EX3300 Switches
91Copyright © 2017, Juniper Networks, Inc.
Chapter 6: Preparation Overview