Chapter 9: Configuration
Creating a New Configuration
Figure 161 Create Virtual Drive - Virtual Drive Settings Window
NOTE If you select Write Back with BBU as the write policy, and no battery
exists, the battery is low or failed, or the battery is running through a
re-learn cycle, the write policy switches to Write Through. This setting
eliminates the risk of data loss in case of a power failure. A message
window notifies you of this change.
4. Change any virtual drive settings, if desired.
See Selecting Virtual Drive Settings, for more information about the virtual drive settings.
5. Click Create Virtual Drive.
The new virtual drive appears under the drive group. The options Update Virtual Drive and Remove Virtual
Drive are available. Update Virtual Drive allows you to change the virtual drive settings, and Remove Virtual
Drive allows you to delete the virtual drive.
6. Click Next.
The Create Virtual Drive - Summary window appears, as shown in the following figure. This window shows the
selections you made for advanced configuration.