LSI Corporation
- 359 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0058 Information Format complete on %s Logged when Format has completed.
0x0059 Information Format started on %s Logged when format unit is started on a PD.
0x005a Critical Hot Spare SMART polling failed on
%s (Error %02x)
Currently not logged.
0x005b Information Drive inserted: %s Logged when drive is inserted and slot/enclosure fields of PD
are updated.
0x005c Warning Drive %s is not supported Logged when the drive is not supported; reason could be the
number of drive has exceeded the MAX supported drives or
an unsupported drive is inserted like a SATA drive in SAS only
enclosure or could be a unsupported drive type.
0x005d Warning Patrol Read corrected medium error
on %s at %lx
Logged when Patrol read has successfully completed
recovery read and recovered data.
0x005e Progress Patrol Read progress on %s is %s Logs patrol read progress, the progress is logged only if the
progress is greater than 1% at an interval of every 15 seconds.
0x005f Fatal Patrol Read found an uncorrectable
medium error on %s at %lx
Logged when Patrol read is unable to recover data.
0x0060 Critical Predictive failure: CDB: %s Logged when a failure is found during smart (predictive
failure) poll.
0x0061 Fatal Patrol Read puncturing bad block on
%s at %lx
Logged when patrol read punctures a block due to
unrecoverable medium error.
0x0062 Information Rebuild aborted by user on %s Logged when the user aborts a rebuild operation.
0x0063 Information Rebuild complete on %s Logged when the rebuild operation on a logical drive on a
physical drive (which may have multiple LDs) is completed.
0x0064 Information Rebuild complete on %s Logged when rebuild operation is completed for all logical
drives on a given physical drive.
0x0065 Critical Rebuild failed on %s due to source
drive error
Logged if one of the source drives for the rebuild operation
fails or is removed.
0x0066 Critical Rebuild failed on %s due to target
drive error
Logged if the target rebuild drive (on which rebuild
operation is going on) fails or is removed from the controller.
0x0067 Progress Rebuild progress on %s is %s Logged to indicate the progress (in percentage) of the
rebuild operation on a given physical drive.
0x0068 Information Rebuild resumed on %s Logged when the rebuild operation on a physical drive
resumes.
0x0069 Information Rebuild started on %s Logged when the rebuild operation is started on a physical
drive.
0x006a Information Rebuild automatically started on %s Logged when the rebuild operation kicks in on a spare.
0x006b Critical Rebuild stopped on %s due to loss of
cluster ownership
Logged when the rebuild operation is stopped due to loss of
ownership.
0x006c Fatal Reassign write operation failed on
%s at %lx
Logged when a check condition or medium error is
encountered for a reassigned write.
0x006d Fatal Unrecoverable medium error during
rebuild on %s at %lx
Logged when the rebuild I/O encounters an unrecoverable
medium error.
0x006e Information Corrected medium error during
recovery on %s at %lx
Logged when recovery completed successfully and fixed a
medium error.
0x006f Fatal Unrecoverable medium error during
recovery on %s at %lx
Logged when the recovery for a failed I/O encounters a
medium error.
0x0070 Information Drive removed: %s Logged when a drive is removed from the controller.