Appendix A: Events and Messages
0x0071 Warning Unexpected sense: %s, CDB%s,
Sense: %s
Logged when an I/O fails due to unexpected reasons and
sense data needs to be logged.
0x0072 Information State change on %s from %s to %s Logged when the state of a drive is changed by the firmware
or by you.
0x0073 Information State change by user on %s from %s
to %s
Not logged by the firmware.
0x0074 Warning Redundant path to %s broken Not logged by the firmware.
0x0075 Information Redundant path to %s restored Not logged by the firmware
0x0076 Information Dedicated Hot Spare Drive %s no
longer useful due to deleted drive
group
Not logged by the firmware.
0x0077 Critical SAS topology error: Loop detected Logged when device discovery fails for a SAS device as a loop
was detected.
0x0078 Critical SAS topology error: Unaddressable
device
Logged when device discovery fails for a SAS device as an
unaddressable device was found.
0x0079 Critical SAS topology error: Multiple ports to
the same SAS address
Logged when device discovery fails for a SAS device multiple
ports with same SAS address were detected.
0x007a Critical SAS topology error: Expander error Not logged by the firmware.
0x007b Critical SAS topology error: SMP timeout Logged when device discovery fails for a SAS device due to
SMP timeout.
0x007c Critical SAS topology error: Out of route
entries
Logged when device discovery fails for a SAS device as
expander route table is out of entries.
0x007d Critical SAS topology error: Index not found Logged when device discovery fails for a SAS device as
expander route table out of entries.
0x007e Critical SAS topology error: SMP function
failed
Logged when device discovery fails for a SAS device due to
SMP function failure.
0x007f Critical SAS topology error: SMP CRC error Logged when device discovery fails for a SAS device due to
SMP CRC error.
0x0080 Critical SAS topology error: Multiple
subtractive
Logged when device discovery fails for a SAS device as a
subtractive-to-subtractive link was detected.
0x0081 Critical SAS topology error: Table to table Logged when device discovery fails for a SAS device as
table-to-table link was detected.
0x0082 Critical SAS topology error: Multiple paths Not logged by the firmware.
0x0083 Fatal Unable to access device %s Logged when the inserted drive is bad and unusable.
0x0084 Information Dedicated Hot Spare created on %s
(%s)
Logged when a drive is configured as a dedicated spare.
0x0085 Information Dedicated Hot Spare %s disabled Logged when a drive is removes as a dedicated spare.
0x0086 Critical Dedicated Hot Spare %s no longer
useful for all drive groups
Logged when an array with a dedicated spare is resized. The
hot spare (dedicated to this array and possibly others) will
not be applicable to other arrays.
0x0087 Information Global Hot Spare created on %s (%s) Logged when a drive is configured as a global hot spare.
0x0088 Information Global Hot Spare %s disabled Logged when a drive configured as global host spare fails or
is unconfigured by you.
0x0089 Critical Global Hot Spare does not cover all
drive groups
Logged when the global hotspare is too small (or doesn't
meet the SAS/SATA restricitons) to cover certain arrays.
0x008a Information Created %s} Logged as soon as the new logical drive created is added to
the firmware configuration.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs