LSI Corporation
- 368 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0136 Information Drive security key from escrow,
verified
Logged when controller lock key is verified from escrow.
0x0137 Information Drive security key changed Logged when controller lock key is re-keyed.
0x0138 Warning Drive security key, re-key operation
failed
Logged when controller lock re-key operation failed.
0x0139 Warning Drive security key is invalid Logged when the controller lock is not valid.
0x013a Information Drive security key destroyed Logged when the controller lock key is destroyed.
0x013b Warning Drive security key from escrow is
invalid
Logged when the controller escrow key is not valid. This
escrow key can not unlock any drive.
0x013c Information VD %s is now secured Logged when secure LD is created.
0x013d Warning VD %s is partially secured Logged when all the drives in the array are not secure.
0x013e Information PD %s security activated Logged when PD security key is set.
0x013f Information PD %s security disabled Logged when security key is removed from an FDE drive.
0x0140 Information PD %s is reprovisioned Logged when PD security is cleared.
0x0141 Information PD %s security key changed Logged when PD lock key is re-keyed.
0x0142 Fatal Security subsystem problems
detected for PD %s
Logged when PD security can not be set.
0x0143 Fatal Controller cache pinned for missing
or offline VD %s
Logged when LD cache is pinned.
0x0144 Fatal Controller cache pinned for missing
or offline VDs: %s
Logged when pinned cache is found during OCR.
0x0145 Information Controller cache discarded by user
for VDs: %s
Logged when LD pinned cache is discarded by the user.
0x0146 Information Controller cache destaged for VD %s Logged when LD pinned cache is recovered.
0x0147 Warning Consistency Check started on an
inconsistent VD %s
Logged when consistency check is started on an inconsistent
LD.
0x0148 Warning Drive security key failure, cannot
access secured configuration
Logged when an invalid lock key is detected.
0x0149 Warning Drive security password from user is
invalid
Not logged.
0x014a Warning Detected error with the remote
battery connector cable
Not logged.
0x014b Information Power state change on PD %s from
%s to %s
Logged when PD power state (spun up, spun down,
in-transition) changes.
0x014c Information Enclosure %s element (SES code
0x%x) status changed
Not logged.
0x014d Information PD %s rebuild not possible as
HDD/CacheCade software mix is not
supported in a drive group
Logged when mixing violation occurs due to HDD/SSD
mismatch.
0x014e Information Replace Drive cannot be started on
PD %s from %s, as HDD/CacheCade
software mix is not supported in a
drive group
Logged when Replace could not be started on a PD because
HDD/CacheCade software mix was not supported in a drive
group.
0x014f Information VD bad block table on %s is cleared Logged when a VD bad block table was cleared.
0x0150 Caution SAS topology error: 0x%lx Logged when a SAS topology error occurred.
0x0151 Information VD cluster of medium errors
corrected for %s at %lx (on %s at %lx)
Logged when medium errors were corrected for a PD for a
LD.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs