Appendix A: Events and Messages
0x011f Warning Foreign import shall result in a
backward incompatible upgrade of
configuration metadata
Currently not used in the firmware.
0x0120 Information Redundant path restored for PD %s Logged when new path is added for the physical drives.
0x0121 Warning Redundant path broken for PD %s Logged when one path is removed.
0x0122 Information Redundant enclosure EMM %s
inserted for EMM %s
Logged when an enclosure is added.
0x0123 Information Redundant enclosure EMM %s
removed for EMM %s
Logged when an enclosure is removed
0x0124 Warning Patrol Read can't be started, as PDs
are either not ONLINE, or are in a VD
with an active process, or are in an
excluded VD
Logged when none of the disks can start PR.
0x0125 Information Replace Drive aborted by user on PD
%s and src is PD %s
Logged when Replace is aborted by the user.
0x0126 Critical Replace Drive aborted on hot spare
%s from %s, as hot spare needed for
rebuild
Logged when Replace is aborted on a Hotspare.
0x0127 Warning Replace Drive aborted on PD %s
from PD %s, as rebuild required in
the array
Logged when Replace is stopped for a higher priority rebuild
operation on a drive.
0x0128 Fatal Controller cache discarded for
missing or offline VD %s
When a VD with cached data goes
offline or missing during runtime, the
cache for the VD is discarded.
Because the VD is offline, the cache
cannot be saved.
Logged when pinned cache lines are discarded for a LD.
0x0129 Information Replace Drive cannot be started as
PD %s is too small for src PD %s
Logged when destination PD is too small for Replace.
0x012a Information Replace Drive cannot be started on
PD %s from PD %s, as SAS/SATA is
not supported in an array
Logged when there is a SAS/SATA mixing violation for the
destination PD.
0x012b Information Microcode update started on PD %s Logged when PD Firmware download starts.
0x012c Information Microcode update completed on PD
%s
Logged when PD Firmware download completes.
0x012d Warning Microcode update timeout on PD %s Logged when PD Firmware download does not complete
and times out.
0x012e Warning Microcode update failed on PD %s Logged when PD Firmware download fails.
0x012f Information Controller properties changed Logged when any of the controller properties has changed.
0x0130 Information Patrol Read properties changed Currently not logged in the firmware.
0x0131 Information CC Schedule properties changed Logged when consistency check scheduling property has
changed.
0x0132 Information Battery properties changed Logged when any of the BBU properties has changed.
0x0133 Warning Periodic Battery Relearn is pending.
Please initiate manual learn cycle as
Automatic learn is not enabled
Logged when BBU periodic relearn is pending.
0x0134 Information Drive security key created Logged when controller lock key is created.
0x0135 Information Drive security key backed up Logged when controller lock key is backed up.