LSI Corporation
- 366 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0107 Warning Foreign configuration table overflow Logged when the number of GUIDs to import exceeds the
total supported by the firmware.
0x0108 Warning Partial foreign configuration
imported, PDs not imported:%s
Logged when all the foreign configuration drives could not
be imported.
0x0109 Information Connector %s is active Logged during initial boot when a SAS MUX connector is
found for the controller.
0x010a Information Board Revision %s Logged during boot.
0x010b Warning Command timeout on PD %s,
CDB:%s
Logged when command to a PD Timesout.
0x010c Warning PD %s reset (Type %02x) Logged when PD is reset.
0x010d Warning VD bad block table on %s is 80% full Logged when number of Bad Blocks entries is at 80 % of what
can be supported in the firmware.
0x010e Fatal VD bad block table on %s is full;
unable to log block %lx (on %s at
%lx)
Logged when number of Bad Blocks exceed what can be
supported in the firmware.
0x010f Fatal Uncorrectable medium error logged
for %s at %lx (on %s at %lx)
Logged when an uncorrectable medium error is detected.
0x0110 Information VD medium error corrected on %s at
%lx
Logged on the corrected medium error.
0x0111 Warning Bad block table on PD %s is 100% full Logged when Bad block table is 100 % Full. Any more media
errors on this physical drive will not be logged in the bad
block table.
0x0112 Warning VD bad block table on PD %s is 100%
full
Logged when Bad block table is 100 % Full. Any more media
errors on this logical drive will not be logged in the bad block
table.
0x0113 Fatal Controller needs replacement, IOP is
faulty
Currently not logged in the firmware.
0x0114 Information Replace Drive started on PD %s from
PD %s
Logged when Replace is started.
0x0115 Information Replace Drive aborted on PD %s and
src is PD %s
Logged when Replace is aborted.
0x0116 Information Replace Drive complete on PD %s
from PD %s
Logged when Replace is completed.
0x0117 Progress Replace Drive progress on PD %s is
%s
Logged to provide the progress of Replace.
0x0118 Information Replace Drive resumed on PD %s
from %s
Logged when Replace operation is resumed.
0x0119 Information Replace Drive automatically started
on PD %s from %s
Logged on automatic start of Replace.
0x011a Critical Replace Drive failed on PD %s due to
source %s error
Logged when the source physical drive of a Replace fails. The
Replace stops and rebuild starts on the destination physical
drive.
0x011b Warning Early Power off warning was
unsuccessful
Currently not logged in the firmware.
0x011c Information BBU FRU is %s Logged only for IBM.
0x011d Information %s FRU is %s Logged if FRU data is present. Logged only for IBM.
0x011e Information Controller hardware revision ID %s Currently not used in the firmware.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs