LSI Corporation
- 365 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x00ea Information Enclosure %s Firmware download in
progress
Logged when Enclosure a Firmware download is in progress.
0x00eb Warning Enclosure %s Firmware download
failed
Logged when Enclosure a Firmware download failed.
0x00ec Warning %s is not a certified drive Logged if the drive is not certified.
0x00ed Information Dirty cache data discarded by user Logged when Dirty cache data is discarded by the user.
0x00ee Information Drives missing from configuration at
boot
Logged when physical drives are missing from configuration
at boot.
0x00ef Information Virtual drives (VDs) missing drives
and will go offline at boot: %s
Logged when virtual drives missing drives and will go offline
at boot.
0x00f0 Information VDs missing at boot: %s Logged when virtual drives missing at boot.
0x00f1 Information Previous configuration completely
missing at boot
Logged when Previous configuration completely missing at
boot.
0x00f2 Information Battery charge complete Logged when Battery charge is completed.
0x00f3 Information Enclosure %s fan %d speed changed Logged when an Enclosure fan speed changed.
0x00f4 Information Dedicated spare %s imported as
global due to missing arrays
Logged when a Dedicated spare is imported as global due to
missing arrays.
0x00f5 Information %s rebuild not possible as SAS/SATA
is not supported in an array
Logged when a rebuild is not possible as SAS/SATA is not
supported in an array.
0x00f6 Information SEP %s has been rebooted as a part
of enclosure firmware download. SEP
will be unavailable until this process
completes.
Logged when SEP has been rebooted as part of enclosure
firmware download. It will be unavailable until reboot
completes.
0x00f7 Information Inserted PD: %s Info: %s Logged when a physical drive is inserted.
0x00f8 Information Removed PD: %s Info: %s Logged when a physical drive is removed.
0x00f9 Information VD %s is now OPTIMAL Logged when a logical drive state changes to OPTIMAL.
0x00fa Warning VD %s is now PARTIALLY DEGRADED Logged when a logical drive state changes to a partially
degraded state.
0x00fb Critical VD %s is now DEGRADED Logged when a logical drive state changes to degraded state.
0x00fc Fatal VD %s is now OFFLINE Logged when a logical drive state changes to offline state.
0x00fd Warning Battery requires reconditioning;
please initiate a LEARN cycle
Logged when a Battery requires reconditioning; please
initiate a LEARN cycle.
0x00fe Warning VD %s disabled because RAID-5 is
not supported by this RAID key
Logged when a virtual drive is disabled because RAID-5 is not
supported by this RAID key.
0x00ff Warning VD %s disabled because RAID-6 is
not supported by this controller
Logged when a virtual drive is disabled because RAID-6 is not
supported by this controller.
0x0100 Warning VD %s disabled because SAS drives
are not supported by this RAID key
Logged when a virtual drive is disabled because SAS drives
are not supported by this RAID key.
0x0101 Warning PD missing: %s Logged to provide information about the missing drive
during boot.
0x0102 Warning Puncturing of LBAs enabled Currently not logged in the firmware.
0x0103 Warning Puncturing of LBAs disabled Currently not logged in the firmware.
0x0104 Critical Enclosure %s EMM %d not installed Logged when Enclosure SIM is not installed.
0x0105 Information Package version %s Prints the Package version number.
0x0106 Warning Global affinity Hot Spare %s
commissioned in a different
enclosure
Logged when a hot spare that is a part of an enclosure is
commissioned in a different enclosure.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs