LSI Corporation
- 364 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x00cf Information Enclosure %s Power supply %d cable
inserted
Logged when the enclosure services process has detected
that the Enclosure Power supply cable is inserted and it was
removed earlier.
0x00d0 Information Enclosure %s Fan %d returned to
normal
Logged when the enclosure services process has detected
that the current status of a fan is good and it was failed
earlier.
0x00d1 Information BBU Retention test was initiated on
previous boot
Logged when the Battery Retention test was initiated on
previous boot.
0x00d2 Information BBU Retention test passed Logged when the Battery Retention test passed successfully.
0x00d3 Critical BBU Retention test failed! Logged when the Battery Retention test failed.
0x00d4 Information NVRAM Retention test was initiated
on previous boot
Logged when the NVRAM Retention test was initiated on
previous boot.
0x00d5 Information NVRAM Retention test passed Logged when the NVRAM Retention test passed successfully.
0x00d6 Critical NVRAM Retention test failed! Logged when the NVRAM Retention test failed.
0x00d7 Information %s test completed %d passes
successfully
Logged when the controller diagnostics test passes
successfully.
0x00d8 Critical %s test FAILED on %d pass. Fail data:
errorOffset=%x goodData=%x
badData=%x
Logged when the controller diagnostics test fails.
0x00d9 Information Self check diagnostics completed Logged when Self check diagnostics is completed.
0x00da Information Foreign Configuration detected Logged when Foreign Configuration is detected.
0x00db Information Foreign Configuration imported Logged when Foreign Configuration is imported.
0x00dc Information Foreign Configuration cleared Logged when Foreign Configuration is cleared.
0x00dd Warning NVRAM is corrupt; reinitializing Logged when NVRAM is corrupt and re-initialized.
0x00de Warning NVRAM mismatch occurred Logged when NVRAM mismatch occurs.
0x00df Warning SAS wide port %d lost link on PHY
%d
Logged when SAS wide port lost link on a PHY.
0x00e0 Information SAS wide port %d restored link on
PHY %d
Logged when a SAS wide port restored link on a PHY.
0x00e1 Warning SAS port %d, PHY %d has exceeded
the allowed error rate
Logged when a SAS PHY on port has exceeded the allowed
error rate.
0x00e2 Warning Bad block reassigned on %s at %lx to
%lx
Logged when a Bad block is reassigned on a drive from a
error sector to a new sector.
0x00e3 Information Controller Hot Plug detected Logged when a Controller Hot Plug is detected.
0x00e4 Warning Enclosure %s temperature sensor %d
differential detected
Logged when an Enclosure temperature sensor differential is
detected.
0x00e5 Information Drive test cannot start. No qualifying
drives found
Logged when Disk test cannot start. No qualifying disks
found.
0x00e6 Information Time duration provided by host is
not sufficient for self check
Logged when Time duration provided by the host is not
sufficient for self check.
0x00e7 Information Marked Missing for %s on drive
group %d row %d
Logged when a physical drive is Marked Missing on an array
at a particular row.
0x00e8 Information Replaced Missing as %s on drive
group %d row %d
Logged when a physical drive is Replaced Missing on an array
at a particular row.
0x00e9 Information Enclosure %s Temperature %d
returned to normal
Logged when an Enclosure temperature returns to normal.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs