LSI Corporation
- 363 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x00ba Critical Enclosure %s is unstable Logged when the enclosure services process reports the
sense errors.
0x00bb Critical Enclosure %s hardware error Logged when a critical or an unrecoverable enclosure failure
has been detected by the enclosure services process.
0x00bc Critical Enclosure %s not responding Logged when there is no response from the enclosure.
0x00bd Information SAS/SATA mixing not supported in
enclosure; Drive %s disabled
Logged when the SAS/SATA mixing in an enclosure is being
violated.
0x00be Information Enclosure (SES) hotplug on %s was
detected, but is not supported
Not reported to the user.
0x00bf Information Clustering enabled Logged when the clustering is enabled in the controller
properties.
0x00c0 Information Clustering disabled Logged when the clustering is disabled in the controller
properties.
0x00c1 Information Drive too small to be used for
auto-rebuild on %s
Logged when the size of the drive is not sufficient for
auto-rebuild.
0x00c2 Information BBU enabled; changing WT virtual
drives to WB
Logged when changing WT virtual drives to WB and the BBU
status is good.
0x00c3 Warning BBU disabled; changing WB virtual
drives to WT
Logged when changing WB virtual drives to WT and the BBU
status is bad.
0x00c4 Warning Bad block table on drive %s is 80%
full
Logged when the Bad block table on a drive is 80% full.
0x00c5 Fatal Bad block table on drive %s is full;
unable to log block %lx
Logged when the Bad block table on a drive is full and not
able to add the bad block in the Bad block table.
0x00c6 Information Consistency Check Aborted due to
ownership loss on %s
Logged when the Consistency Check is aborted due to
ownership is lost.
0x00c7 Information Background Initialization (BGI)
Aborted Due to Ownership Loss on
%s
Logged when the Background Initialization (BGI) is aborted
due to ownership loss.
0x00c8 Critical Battery/charger problems detected;
SOH Bad
Logged when the battery is not presented or removed and
SOH is bad.
0x00c9 Warning Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); warning threshold
exceeded
Logged when the Single-bit ECC errors exceeded the
warning threshold.
0x00ca Critical Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); critical threshold
exceeded
Logged when the Single-bit ECC errors exceeded the critical
threshold.
0x00cb Critical Single-bit ECC error: ECAR=%x,
ELOG=%x, (%s); further reporting
disabled
Logged when the Single-bit ECC errors exceeded all the
thresholds and disable further logging.
0x00cc Critical Enclosure %s Power supply %d
switched off
Logged when the enclosure services process has detected
that the Enclosure Power supply is switched off and it was
switched on earlier.
0x00cd Information Enclosure %s Power supply %d
switched on
Logged when the enclosure services process has detected
that the Enclosure Power supply is switched on and it was
switched off earlier.
0x00ce Critical Enclosure %s Power supply %d cable
removed
Logged when the enclosure services process has detected
that the Enclosure Power supply cable is removed and it was
inserted earlier.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs