LSI Corporation
- 370 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x0171 Warning %s is not available Logged when a LD was not available.
0x0172 Information %s is available Logged when a LD was available.
0x0173 Information %s is used for CacheCade with
capacity 0x%lx logical blocks
Logged when a LD was used for CacheCade with the
indicated capacity in logical blocks.
0x0174 Information %s is using CacheCade %s Logged when a LD was using CacheCade.
0x0175 Information %s is no longer using CacheCade %s Logged when a LD was no longer using CacheCade.
0x0176 Critical Snapshot deleted due to resource
constraints for %s in snapshot
repository %s
Logged when the snapshot is deleted due to resource
constraints in snapshot repository.
0x0177 Warning Auto Snapshot failed for %s in
snapshot repository %s
Logged when the Auto Snapshot is failed for a VD in
snapshot repository.
0x0178 Warning Controller reset on-board expander Logged when the chip reset issued to on-board expander.
0x0179 Warning CacheCade (%s) capacity changed
and is now 0x%lx logical blocks
Logged when the CacheCade capacity is changed along with
the current capacity.
0x017a Warning Battery cannot initiate transparent
learn cycles
Logged when the Battery cannot initiate transparent learn
cycles.
0x017b Information Premium feature %s key was applied
for - %s
Logged when the Premium feature key was applied.
0x017c Information Snapshot schedule properties
changed on %s
Logged when the Snapshot schedule properties changed.
0x017d Information Snapshot scheduled action is due on
%s
Logged when the Snapshot scheduled action is due.
0x017e Information Performance Metrics: collection
command 0x%lx
Logged during the Performance Metrics collection.
0x017f Information Premium feature %s key was
transferred - %s
Logged when the Premium feature key was transferred.
0x0180 Information Premium feature serial number %s Logged when displaying the Premium feature serial number.
0x0181 Warning Premium feature serial number
mismatched. Key-vault serial num -
%s
Logged when Premium feature serial number mismatched.
0x0182 Warning Battery cannot support data
retention for more than %d hours.
Please replace the battery
Logged during the Battery monitoring and it displays the
remaining data retention time of the battery.
0x0183 Information %s power policy changed to %s
(from %s)
Logged when the power policy of an LD is changed.
0x0184 Warning %s cannot transition to max power
savings
Logged when LD cannot transition to max power savings.
0x0185 Information Host driver is loaded and operational This event is not reported to the user.
0x0186 Information %s mirror broken Logged when the mirror is broken for an LD.
0x0187 Information %s mirror joined Logged when joining the LD with its broken mirror.
0x0188 Warning %s link %d failure in wide port This event is not reported to the user.
0x0189 Information %s link %d restored in wide port This event is not reported to the user.
0x018a Information Memory module FRU is %s This event is not reported to the user.
0x018b Warning Cache-vault power pack is
sub-optimal. Please replace the pack
This event is not reported to the user.
0x018c Warning Foreign configuration auto-import
did not import any drives
Logged when the Foreign configuration auto-import did not
import any drives.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs