Appendix A: Events and Messages
0x018d Warning Cache-vault microcode update
required
Logged when the BMU is not in Normal mode and
Cache-vault microcode update required.
0x018e Warning CacheCade (%s) capacity exceeds
maximum allowed size, extra
capacity is not used
Logged when CacheCade capacity exceeds maximum
allowed size, extra capacity is not used.
0x018f Warning LD (%s) protection information lost Logged when the protection information is lost for an LD.
0x0190 Information Diagnostics passed for %s Logged when the SHIELD Diagnostics passed for a PD.
0x0191 Critical Diagnostics failed for %s Logged when the SHIELD Diagnostics failed for a PD.
0x0192 Information Server Power capability Diagnostic
Test Started
Logged when the Server Power capability Diagnostic Test
starts.
0x0193 Information Drive Cache settings enabled during
rebuild for %s
Logged when the Drive Cache settings enabled during
rebuild for a PD.
0x0194 Information Drive Cache settings restored after
rebuild for %s
Logged when the Drive Cache settings restored after rebuild
for a PD.
0x0195 Information Drive %s commissioned as
Emergency spare
Logged when the Drive commissioned as Emergency spare.
0x0196 Warning Reminder: Potential non-optimal
configuration due to drive %s
commissioned as emergency spare
Logged when the PD being imported is an Emergency Spare.
0x0197 Information Consistency Check suspended on %s Logged when the Consistency Check is suspended on an LD.
0x0198 Information Consistency Check resumed on %s Logged when the Consistency Check is resumed on an LD.
0x0199 Information Background Initialization suspended
on %s
Logged when the Background Initialization is suspended on
an LD.
0x019a Information Background Initialization resumed
on %
Logged when the Background Initialization is resumed on an
LD.
0x019b Information Reconstruction suspended on %s Logged when the Reconstruction is suspended on an LD.
0x019c Information Rebuild suspended on % Logged when the Rebuild is suspended on a PD.
0x019d Information Replace Drive suspended on %s Logged when the Replace is suspended on a PD.
0x019e Information Reminder: Consistency Check
suspended on %
Logged as a reminder when the Consistency Check is
suspended on an LD.
0x019f Information Reminder: Background Initialization
suspended on %s
Logged as a reminder when the Background Initialization is
suspended on an LD.
0x01a0 Information Reminder: Reconstruction
suspended on %s
Logged as a reminder when the Reconstruction is suspended
on an LD.
0x01a1 Information Reminder: Rebuild suspended on %s Logged as a reminder when the Rebuild is suspended on a
PD.
0x01a2 Information Reminder: Replace Drive suspended
on %s
Logged as a reminder when Replace is suspended on a PD.
0x01a3 Information Reminder: Patrol Read suspended Logged as a reminder when the Patrol Read is suspended.
0x01a4 Information Erase aborted on %s Logged when the Erase is aborted on a PD.
0x01a5 Critical Erase failed on %s (Error %02x) Logged when the Erase is failed on a PD along with the error.
0x01a6 Progress Erase progress on %s is %s Logged to display the Erase progress on a PD along with its
current progress.
0x01a7 Information Erase started on %s Logged when Erase is started on a PD.
0x01a8 Information Erase completed on %s Logged when the Erase is completed on a PD.
0x01a9 Information Erase aborted on %s Logged when the Erase is aborted on an LD.
Number
Severity