EasyManua.ls Logo

Lenovo ThinkServer RD650 - Page 371

Lenovo ThinkServer RD650
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LSI Corporation
- 371 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix A: Events and Messages
0x018d Warning Cache-vault microcode update
required
Logged when the BMU is not in Normal mode and
Cache-vault microcode update required.
0x018e Warning CacheCade (%s) capacity exceeds
maximum allowed size, extra
capacity is not used
Logged when CacheCade capacity exceeds maximum
allowed size, extra capacity is not used.
0x018f Warning LD (%s) protection information lost Logged when the protection information is lost for an LD.
0x0190 Information Diagnostics passed for %s Logged when the SHIELD Diagnostics passed for a PD.
0x0191 Critical Diagnostics failed for %s Logged when the SHIELD Diagnostics failed for a PD.
0x0192 Information Server Power capability Diagnostic
Test Started
Logged when the Server Power capability Diagnostic Test
starts.
0x0193 Information Drive Cache settings enabled during
rebuild for %s
Logged when the Drive Cache settings enabled during
rebuild for a PD.
0x0194 Information Drive Cache settings restored after
rebuild for %s
Logged when the Drive Cache settings restored after rebuild
for a PD.
0x0195 Information Drive %s commissioned as
Emergency spare
Logged when the Drive commissioned as Emergency spare.
0x0196 Warning Reminder: Potential non-optimal
configuration due to drive %s
commissioned as emergency spare
Logged when the PD being imported is an Emergency Spare.
0x0197 Information Consistency Check suspended on %s Logged when the Consistency Check is suspended on an LD.
0x0198 Information Consistency Check resumed on %s Logged when the Consistency Check is resumed on an LD.
0x0199 Information Background Initialization suspended
on %s
Logged when the Background Initialization is suspended on
an LD.
0x019a Information Background Initialization resumed
on %
Logged when the Background Initialization is resumed on an
LD.
0x019b Information Reconstruction suspended on %s Logged when the Reconstruction is suspended on an LD.
0x019c Information Rebuild suspended on % Logged when the Rebuild is suspended on a PD.
0x019d Information Replace Drive suspended on %s Logged when the Replace is suspended on a PD.
0x019e Information Reminder: Consistency Check
suspended on %
Logged as a reminder when the Consistency Check is
suspended on an LD.
0x019f Information Reminder: Background Initialization
suspended on %s
Logged as a reminder when the Background Initialization is
suspended on an LD.
0x01a0 Information Reminder: Reconstruction
suspended on %s
Logged as a reminder when the Reconstruction is suspended
on an LD.
0x01a1 Information Reminder: Rebuild suspended on %s Logged as a reminder when the Rebuild is suspended on a
PD.
0x01a2 Information Reminder: Replace Drive suspended
on %s
Logged as a reminder when Replace is suspended on a PD.
0x01a3 Information Reminder: Patrol Read suspended Logged as a reminder when the Patrol Read is suspended.
0x01a4 Information Erase aborted on %s Logged when the Erase is aborted on a PD.
0x01a5 Critical Erase failed on %s (Error %02x) Logged when the Erase is failed on a PD along with the error.
0x01a6 Progress Erase progress on %s is %s Logged to display the Erase progress on a PD along with its
current progress.
0x01a7 Information Erase started on %s Logged when Erase is started on a PD.
0x01a8 Information Erase completed on %s Logged when the Erase is completed on a PD.
0x01a9 Information Erase aborted on %s Logged when the Erase is aborted on an LD.
Number
Severity
Level
Event Text Generic Conditions when Each Event Occurs

Table of Contents

Other manuals for Lenovo ThinkServer RD650

Related product manuals