LSI Corporation
- 381 -
12Gb/s MegaRAID SAS Software User Guide
March 2014
Appendix B: 3ware CLI Commands to StorCLI Command Conversion
Virtual Drive Commands
Start initialization (writing 0s) on the
virtual drive.
/cx/ux start verify
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization.
/cx/vx start init [Full]
Stop an ongoing initialization on the
virtual drive.
/cx/ux stop verify
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization
/cx/vx stop init
Show a snapshot of the ongoing
initialization, if any.
/cx/ux show [all]
NOTE Only the bios can do a foreground
initialization. A background initialization does
otherwise. A verify starts a back ground initialization.
/cx/vx show init
Start a consistency check on the
virtual drive.
/cx/ux start verify /cx/vx start cc
Stop a consistency check on the
virtual drive.
/cx/ux stop verify /cx/vx stop cc
Reconstruct the selected virtual disk
to a new RAID level.
/cx/ux migrate type=<RaidType>
[disk=<p:-p..>] [strip=<size>]
[noscan] [nocache] [autoverify]
[group=<3|4|5|6|7|8|9|10|11|12|13|1
4|15|16>]
RaidType={ raid0, raid1, raid5,
raid10, raid50, single, raid6 }
/cx/vx start migrate
<type=raidlevel> [option=<add |
remove> disk=<e1:s1,e2:s2 ..> ]
/cx/vx show migrate
Change the power-saving setting on
the virtual drive.
/cx/ux set powersavestandbytimer=<5
to 999>
/cx/vx set ds=<default | Auto | None
| Max | MaxNoCache>
Description 3Ware CLI Command StorCLI Command