15 Parameter reference
15.2 Parameter list
1024
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00938
C00939
C00940
C00941
Parameter | Name:
C00938 | PSM: Maximum motor current field weakening
Data type: UNSIGNED_16
Index: 23637
d
= 5C55
h
From version 11.00.00
Field weakening for synchronous motors
Setting range (min. value | unit | max. value) Lenze setting
0.00 % 500.00 30.00 %
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00939 | Ultimate motor current
Data type: UNSIGNED_16
Index: 23636
d
= 5C54
h
From version 10.00.00
Setting range (min. value | unit | max. value) Lenze setting
0.0 A 3000.0 3000.0 A
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00940 | L_ConvW numerator
Data type: INTEGER_16
Index: 23635
d
= 5C53
h
From version 04.00.00
Setting range (min. value | unit | max. value)
-32767 32767
Subcodes Lenze setting Info
C00940/1 1 L_ConvW_1
: Numerator
C00940/2 1 L_ConvW_2
: Numerator
C00940/3 1 L_ConvW_3
: Numerator
C00940/4 1 L_ConvW_4
: Numerator
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00941 | L_ConvW denominator
Data type: INTEGER_16
Index: 23634
d
= 5C52
h
From version 04.00.00
Setting range (min. value | unit | max. value)
1 32767
Subcodes Lenze setting Info
C00941/1 1 L_ConvW_1
: Denominator
C00941/2 1 L_ConvW_2
: Denominator
C00941/3 1 L_ConvW_3
: Denominator
C00941/4 1 L_ConvW_4
: Denominator
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1