15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00942
C00950
C00951
Parameter | Name:
C00942 | L_ConvW conversion method
Data type: UNSIGNED_8
Index: 23633
d
= 5C51
h
From version 04.00.00
Selection list
0 no conversion
1 from [%] into [incr./ms]
2from [incr./ms] into [%]
3Factors signed
4Factors unsigned
Subcodes Lenze setting Info
C00942/1 0: No conversion L_ConvW_1
: Conversion method
C00942/2 0: No conversion L_ConvW_2
: Conversion method
C00942/3 0: No conversion L_ConvW_3
: Conversion method
C00942/4 0: No conversion L_ConvW_4
: Conversion method
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00950 | L_Interpolator_1: Activation FB functions
Data type: UNSIGNED_8
Index: 23625
d
= 5C49
h
From version 04.00.00
The L_Interpolator_1
FB: Activation of signal interpolation and signal monitoring
Selection list
0Off
1On
Subcodes Lenze setting Info
C00950/1 0: Off L_Interpolator_1
: Signal interpolation
C00950/2 0: Off L_Interpolator_1: Signal monitoring
C00950/3 0: Off L_Interpolator_1
: Master value monitoring
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00951 | L_Interpolator_1: No. of interpolation steps
Data type: UNSIGNED_16
Index: 23624
d
= 5C48
h
From version 04.00.00
The L_Interpolator_1
FB: No. of interpolation steps
Setting range (min. value | unit | max. value) Lenze setting
0 65535 1
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1