EasyManua.ls Logo

Lenze 8400 - Page 1106

Lenze 8400
1590 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15 Parameter reference
15.2 Parameter list
1106
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02216
C02217
C02218
Parameter | Name:
C02216 | LS_WriteParamList: Slip compensation
Data type: INTEGER_16
Index: 22359
d
= 5757
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
-100.00 % 100.00
Subcodes Lenze setting Info
C02216/1 2.67 % LS_WriteParamList
: c21_val1
C02216/2 2.67 % LS_WriteParamList
: c21_val2
C02216/3 2.67 % LS_WriteParamList
: c21_val3
C02216/4 2.67 % LS_WriteParamList
: c21_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02217 | LS_WriteParamList: Imax in motor mode
Data type: UNSIGNED_16
Index: 22358
d
= 5756
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.00 A 655.35
Subcodes Lenze setting Info
C02217/1 47.00 A LS_WriteParamList
: c22_val1
C02217/2 47.00 A LS_WriteParamList
: c22_val2
C02217/3 47.00 A LS_WriteParamList
: c22_val3
C02217/4 47.00 A LS_WriteParamList
: c22_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02218 | LS_WriteParamList: Imax in generator mode
Data type: INTEGER_16
Index: 22357
d
= 5755
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.00 % 100.00
Subcodes Lenze setting Info
C02218/1 100.00 % LS_WriteParamList
: c23_val1
C02218/2 100.00 % LS_WriteParamList
: c23_val2
C02218/3 100.00 % LS_WriteParamList
: c23_val3
C02218/4 100.00 % LS_WriteParamList
: c23_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100