15 Parameter reference
15.2 Parameter list
1122
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02281
C02284
C02285
Parameter | Name:
C02281 | LS_WriteParamList: VFC: Time const. slip comp.
Data type: UNSIGNED_16
Index: 22294
d
= 5716
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
1 ms 6000
Subcodes Lenze setting Info
C02281/1 100 ms LS_WriteParamList
: c966_val1
C02281/2 100 ms LS_WriteParamList
: c966_val2
C02281/3 100 ms LS_WriteParamList
: c966_val3
C02281/4 100 ms LS_WriteParamList
: c966_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02284 | LS_WriteParamList: VFC: limitation V/f +encoder
Data type: UNSIGNED_16
Index: 22291
d
= 5713
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.00 Hz 100.00
Subcodes Lenze setting Info
C02284/1 10.00 Hz LS_WriteParamList
: c971_s1_val1
C02284/2 10.00 Hz LS_WriteParamList
: c971_s1_val2
C02284/3 10.00 Hz LS_WriteParamList
: c971_s1_val3
C02284/4 10.00 Hz LS_WriteParamList
: c971_s1_val4
C02284/5 100.00 Hz LS_WriteParamList
: c971_s2_val1
C02284/6 100.00 Hz LS_WriteParamList
: c971_s2_val2
C02284/7 100.00 Hz LS_WriteParamList
: c971_s2_val3
C02284/8 100.00 Hz LS_WriteParamList
: c971_s2_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C02285 | LS_WriteParamList: VFC: Vp V/f +encoder
Data type: UNSIGNED_16
Index: 22290
d
= 5712
h
From version 12.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Setting range (min. value | unit | max. value)
0.000 Hz/Hz 64.000
Subcodes Lenze setting Info
C02285/1 0.100 Hz/Hz LS_WriteParamList
: c972_val1
C02285/2 0.100 Hz/Hz LS_WriteParamList
: c972_val2
C02285/3 0.100 Hz/Hz LS_WriteParamList
: c972_val3
C02285/4 0.100 Hz/Hz LS_WriteParamList
: c972_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1000