Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 1133
15 Parameter reference
15.2 Parameter list
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C02314
C02315
C02556
C02580
Parameter | Name:
C02314 | Reserved
Data type: UNSIGNED_8
Index: 22261
d
= 56F5
h
This code is for device-internal use only and must not be written to by the user!
Parameter | Name:
C02315 | LS_WriteParamList: Manual entry of motor type
Data type: UNSIGNED_8
Index: 22260
d
= 56F4
h
From version 14.00.00 onwards: Parameter values (1st value ... 4th value) for optional motor data change-over
Selection list
0Automatic
1ASM
2PSM
Subcodes Lenze setting Info
C02315/1 0: Automatic LS_WriteParamList
: c1001_s1_val1
C02315/2 0: Automatic LS_WriteParamList
: c1001_s1_val2
C02315/3 0: Automatic LS_WriteParamList
: c1001_s1_val3
C02315/4 0: Automatic LS_WriteParamList
: c1001_s1_val4
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02556 | Position controller: Limitation
Data type: INTEGER_32
Index: 22019
d
= 5603
h
Setting range (min. value | unit | max. value)
0 Incr. 2147483647
Subcodes Lenze setting Info
C02556/1 65536 incr. Following error limit
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C02580 | Holding brake: Operating mode
Data type: UNSIGNED_8
Index: 21995
d
= 55EB
h
Selection of the operating mode for holding brake control
Holding brake control
Selection list (Lenze setting printed in bold) Info