17 Function library
17.2 System blocks | LS_ParReadWrite_1-6
1553
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C01092/1...6 Error status
•If bFail = TRUE:
Error status is displayed.
•Subcode1 = LS_ParReadWrite_1
Subcode 2 = LS_ParReadWrite_2
...
Subcode 6 = LS_ParReadWrite_6
0No error
33803 Invalid data type (e.g. STRING)
33804 Limit violation
33806 Invalid code
33813 No element of the selection list
33815 Writing of the parameter not
permitted
33816 Writing of the parameter only
permitted if controller is inhibited
33829 Invalid subcode
33865 No parameter with subcodes
C01093/1...6
(from version 06.00.00)
Arithmetic mode
Lenze setting:"0: No arithmetic"
Arithmetic function
0 No arithmetic
1 In16Bit: LW=+/-32767
2 In16Bit: HW=+/-; LW=0..65535
3 In32Bit: HW_LW=+/-2147483647
C01094/1...6
(from version 06.00.00)
-32767 32767 Counter
For internal conversion in
arithmetic modes 1 ... 3.
•Lenze setting: 1
C01095/1...6
(from version 06.00.00)
1 32767 Denominator
For internal conversion in
arithmetic modes 1 ... 3.
•Lenze setting: 1