Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23 455
7 Technology applications
7.4 TA "Table positioning"
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.4.3.6 PC
Connection Assignment Connection Assignment
X101/NC-NO LA_TabPos.bDriveFail
X5/RFR LA_TabPos.bFailReset X3/A1U -
X5/DI1 - X3/A1I -
X5/DI2 - X3/A2U -
X5/DI3 - X3/A2I -
X5/DI4 - X3/O1U LA_TabPos.nMotorSpeedAct_a
10 V ≡ 100 % reference speed (C00011
)
X5/DI5 - X3/O1I
X5/DI6 - X3/O2U LA_TabPos.nMotorCurrent_a
10V ≡ 100% of I
max_mot
(C00022)
X5/DI7 - X3/O2I
X107/BD1 LA_TabPos.bMBrakeReleaseOut X4/DO1 LA_TabPos.bDriveReady
X107/BD2 - X4/DO2 LA_TabPos.bInTarget
X4/DO3 LA_TabPos.bHomePosAvailable
CG
CL
CH
X107 X4
24B 24O
GB DO1
BD2 DO3
GO
BD1 DO2
X1
+
M
+
==
X5
A2I
AR
COM
A1U
NC
A2U
A1I
NO
X3
DI3
DI2
DI4
DI5
DI6
DI7
GI
24I
DI1
RFR
GA
O1U
O1I
O2U
O2I
X101
24E
+
=
Controller enable
External
supply
24 V DC
DriveReady
Load mechanicals
in target position
Home position known
Actual speed value (V)
Actual speed value (I)
Act. mot. current val. (V)
Act. mot. current val. (I)
MBrakeReleaseOut