15 Parameter reference
15.2 Parameter list
830
Lenze · 8400 HighLine · Reference manual · DMS 12.0 EN · 06/2017 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C00078
C00079
C00080
Parameter | Name:
C00078 | SC: Tn field controller
Data type: UNSIGNED_16
Index: 24497
d
= 5FB1
h
Reset time Tn of the field controller for servo control (SC)
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered
automatically.
Setting range (min. value | unit | max. value) Lenze setting
0.0 ms 6000.0 power-related (see table
)
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 10
Parameter | Name:
C00079 | SC: Settings
Data type: UNSIGNED_8
Index: 24496
d
= 5FB0
h
Configuration of different options for servo control (SC) and sensorless control for synchronous motors (SLPSM)
Selection list
0Off
1On
Subcodes Lenze setting Info
C00079/1 0: Off SC
: Current controller - feedforward control
Please observe the notes regarding this function in
the chapter "Feedforward control of the current
controller"!
C00079/2 1: On SC
: Adapt. VP in the field weakening range
Speed-dependent adaptive field weakening
controller.
C00079/3 0: Off SC
: n-ctrl anti-wind-up
"Anti-wind-up" effect of the speed controller in case
of an output voltage limitation in the field weakening
range.
C00079/4 1: On Field weakening for synchronous motors
From version 11.00.00
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00080 | Override point of field weakening
Data type: INTEGER_16
Index: 24495
d
= 5FAF
h
Offset of the override point for field weakening
In the V/f characteristic control mode (VFCplus
), the stall protection function or the max. permissible current in
the field weakening range can be adapted.
Setting range (min. value | unit | max. value) Lenze setting
-500 Hz 500 0Hz
Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1