C00159
Value is bit-coded:
Bit 0 Terminal controller enable
Bit 1 CAN control word
Bit 2 MCI control word
Bit 3 SwitchOn
Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Internal signal
Bit 8 Reserved
Bit 9 Energy saving mode
Bit 10 AutoStartLock
Bit 11 Motor parameter identification
Bit 12 Automatic brake operation
Bit 13 DCB-IMP
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00158 | Cause of controller inhibit
Data type: UNSIGNED_16
Index: 24417
d
= 5F61
h
Parameter | Name:
C00159 | Cause of quick stop QSP
Data type: UNSIGNED_16
Index: 24416
d
= 5F60
h
Bit coded display of the cause/source of the quick stop
Display area (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded:
Bit 0 Reserved
Bit 1 CAN control word
Bit 2 MCI control word
Bit 3 Reserved
Bit 4 Application
Bit 5 Device command
Bit 6 Error response
Bit 7 Internal signal
Bit 8 Reserved
Bit 9 Energy saving mode
Bit 10 Operating system of
Bit 11 Reserved
Bit 12 MCK
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Read access Write access CINH PLC STOP No transfer COM MOT